DanHam dc45bd381c Manually set up all required for remote management. Use in-built FW rules
Use of 'winrm quickconfig' can sometimes cause the Packer build to fail
shortly after the WinRM connection is established.

* When executed the 'winrm quickconfig -q' command configures the
  firewall to allow management messages to be sent over HTTP (port 5985)
* This undoes the previous command in the script that configured the
  firewall to prevent this access.
* The upshot is that the system is configured and ready to accept WinRM
  connections earlier than intended.
* If Packer establishes its WinRM connection immediately after execution
  of the 'winrm quickconfig -q' command, the later commands within the
  script that restart the WinRM service cause the established
  connection, and consequently, the overall build to fail.